A subset of test files in an order the suite was not written for failed 3
test_init.py::TestImportStep tests with ModuleNotFoundError: voluptuous, while the
full suite stayed green. Two order-only mechanisms, both now fixed at the source:
1. entity_stublib.install() guarded on ONE sentinel
(`homeassistant.components.media_player`). A file whose teardown popped
`voluptuous` but left the sentinel turned the next file's install() into a no-op,
so importing config_flow failed. The guard now checks every face a file scopes on
(`_STUB_FACES`, derived from ENTITIES_STUB_NAMES so the two cannot drift) and
rebuilds the set when anything is missing. install() also registers the
`homeassistant.helpers.selector` face itself, which the per-file installers had
been adding separately — without it the derived list would never be complete.
2. Teardowns restored only the names their file had listed, so a module the file
loaded (`nsh.diagnostics`, `nsh.media_player`) survived into the next file still
holding stub objects — a stub exception class, the redact helper — that had since
been replaced; comparisons against the new objects then failed (5 tests in
test_command_routing on an unlucky order). Every file now ends through
entity_stublib.snapshot_modules()/restore_modules(), which drops EVERYTHING the
file created under the harness namespaces (homeassistant/voluptuous/nsh) and puts
back everything it replaced. Hand-written lists were the bug, so there is none to
keep in sync.
The t7 no-leak discipline is unchanged: a file's stubs still never reach another
file, and a file's loaded modules still do not survive it. A session-scoped baseline
install was tried first and rejected: files whose own installer guards on "the stubs
are already there" skipped installing their richer faces, which produced exactly the
inconsistent state a baseline is meant to prevent (10 test_standalone_setup failures).
tests/test_harness_scoping.py: the sentinel poisoning, the wholesale-rebuild
invariant, a teardown that removes what the file loaded, the stale-object case
(diagnostics vs the redact helper), and — because order is the thing under test —
two subprocess runs of the reported orderings.
Verified: the reported order (test_command_routing, test_protocol_transport,
test_standalone_setup, test_init) 152 passed / 1 skipped; the minimal pair both ways;
the previously failing 6-test order now 167 passed; every test file in REVERSE
alphabetical order 369 passed / 2 skipped; two scrambled thirds green; full suite
369 / 2 and 370 / 1 with androidtvremote2; ruff clean.
ENTRY_VERSION = 3, declared once in const.py and reused as the flow's VERSION so
the stored shape and the migration cannot drift.
v2 → v3 mirrors the two shape changes:
* the duplicated address fields collapse into CONF_HOST — the protocol host
wins, else the ADB host (both name the same Shield), reading options first and
data second so a hand-written seed is covered too;
* the androidtv-entity key is dropped from data AND options with a logged note
naming the dropped entity (the old value would only mislead now that nothing
reads it).
A v1 entry still travels the whole way in one call (the v1→v2 protocol defaults
are applied, then the v3 collapse). Downgrades (version > 3) are rejected so HA
can offer a rollback, and the current version is a no-op.
Existing entries carrying the entity key keep working until the migration runs:
nothing reads it anymore (the c1 commit), which is exactly why the migration can
be a plain removal.
Test note: my first version of the version-parity pin called a bare
entity_stublib.install() and leaked the shallow stub set into the entity-module
loader of later tests (STATE_PAUSED/entity_available import failures). It now
uses the file's scoped harness, like every other test there.
Verified: 316 passed / 2 skipped, 317 / 1 with androidtvremote2, ruff clean,
drift engine exit 0 on HEAD (36 call arguments — one more awaited/checked call).
The two address fields were the same Shield spelled twice, and every bug in the
zeroconf/IP-change path came from keeping them in sync. One field now:
* const.CONF_HOST replaces CONF_ADB_HOST / CONF_PROTOCOL_HOST in the setup form,
the options page, the pairing forms, the reconfigure/reauth seeding and the
description copy. ADB port 5555 stays the only port field;
* helpers.entry_host(entry) is the single resolver (options first, then data);
resolve_adb_config and the protocol settings both go through it, so both
transports read the same value at call time (the t32 F1 factory re-read keeps
working: the NEXT built poller sees the new address);
* helpers.seed_host / seed_adb_enabled own the YAML seed's shape rule. A block
may use `host` or the legacy protocol_host/adb_host keys — t41 keeps the old
spelling working — and t32 F4's outcome is unchanged: a protocol-only block
leaves ADB off, an address (or an explicit adb_enabled) turns it on;
* the zeroconf IP-change path collapses the t21-F2 per-host dance into one rule:
the discovery address IS the entry's address, so the entry is updated when it
differs and left alone when it matches. The blank-self-heal and
deliberately-different-ADB-host cases are gone with the duplication — a
second address field cannot express them anymore, and the tests now pin that
(previously "an explicit override is never clobbered");
* the options page exposes the protocol toggle it never had (the page could turn
ADB off but not the protocol);
* button.py (granted to this task) reads the entry's own address instead of
another integration's entity.
The v3 entry migration that maps existing adb_host/protocol_host onto CONF_HOST
and drops the androidtv key lands in the next commit; HA runs migrations before
setup, so an existing entry is never read with the old shape.
Verified: 311 passed / 2 skipped, 312 / 1 with androidtvremote2, ruff clean,
drift engine exit 0 on HEAD. The UI-copy contract tests (every rendered field
has a label in strings.json AND translations/en.json, key trees identical, host
errors name the field) drove the string edits.
"Continue without protocol pairing" switched the transport off for good: the
options flow carries no protocol fields, so nothing in the UI could ever turn
it back on, and the skip copy promised nothing about it (t34 F1). The entry now
answers Home Assistant's Reconfigure action:
* async_step_reconfigure (audit G5) seeds the flow from the entry (title, adb
host/port/enabled, androidtv entity for the host fallback) and re-runs the
pairing step — the address is editable, the Shield shows a PIN, and
_finish_reconfigure persists protocol_enabled=True plus the address that just
paired (so the transport no longer depends on the ADB fallback), adopts the
paired MAC when it differs, and updates + reloads the entry. HA derives the
"reconfigure_successful" abort from the flow source. A Reconfigure visit that
clicks skip aborts honestly with "reconfigure_skipped" (entry untouched), and
an entry that is gone aborts with "reconfigure_entry_missing".
* the skip data_description now states the truth — the transport stays off
until you pair it — and names the later path (the integration's entry menu >
Reconfigure).
* a host corrected on the pairing form now DROPS the session started against the
old address and restarts pairing there, so the typed address is authoritative
instead of being paired against the stale one.
* the success path no longer runs _abort_if_unique_id_configured for a flow
that already owns an entry: core looks the domain up by unique_id, so
re-pairing an entry aborted on itself as "already_configured" (this also
unblocked reauth). The fresh-setup path is unchanged.
* adjacent fix while wiring the same call: _finish_reauth passed
`options_updates`, which core's async_update_reload_and_abort does not accept
(the kwarg is `options`, REPLACE) — the reauth path would have raised
TypeError in production. Both paths now pass `options` and the test stubs
mirror the real signature.
Tests: tests/test_config_flow_ux.py::TestProtocolReconfigure drives reconfigure
from a protocol-disabled entry through to updated options (transport on, host
persisted, other options kept, MAC adopted, reload recorded), a corrected host
reopening the PIN step against the new address, the skip abort, and the
missing-entry abort; TestCopyContract gained the F1b copy pin. Against HEAD's
config_flow.py all four reconfigure tests fail (no async_step_reconfigure).
Verified: uvx --with pytest-asyncio pytest tests -q → 281 passed, 1 skipped;
uvx --with pytest-asyncio --with androidtvremote2 pytest tests -q → 282 passed;
uvx ruff check custom_components tests → clean.